SAVE THESE INSTUCTIONS - This manual contains important instructions that should be followed during installation and maintenance of the Smart-UPS and…
DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a hazardous situation…
Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. • Adhere to all national and local electrical codes. • All…
Servicing of user replaceable batteries should to be performed or supervised by personnel knowledgeable about batteries and required precautions. • It is not…
The UPS contains internal batteries and may present a shock hazard even when disconnected from the branch circuit (mains). Before installing or servicing the…
WARNING: This is a category C2 UPS product. In a residential environment, this product may cause radio interference, in which case the user may be required to…
The APC™ by Schneider Electric Smart-UPS™ C is a high performance uninterruptible power supply (UPS). The UPS provides protection for electronic equipment from…
For additional specifications, refer to the APC by Schneider Electric web site at www.apc.com. Weight specifications UPS + Battery Battery 1000 VA models 20.48…
Front panel features Display interface 1000VA 120/230 Vac Bezel Battery Internal battery connector 3000 VA 230 Vac 1500 VA 120/230 Vac 2000 VA 230 Vac…
Display interface 1000VA 120/230 Vac Bezel Battery Internal battery connector 3000 VA 230 Vac 1500 VA 120/230 Vac 2000 VA 230 Vac su0563c su0936a su0630c
Installation For UPS installation information, refer to the Installation Guide for the Smart-UPS C 1000/1500/2000/ 3000 VA Rack-Mount 2U included with the UPS.…
For UPS installation information, refer to the Installation Guide for the Smart-UPS C 1000/1500/2000/ 3000 VA Rack-Mount 2U included with the UPS. The…
Note: The UPS will charge to 90% capacity in the first three hours of normal operation. Do not expect full battery runtime capability during this initial…
Display panel features Low sensitivity Medium sensitivity High sensitivity (Default) 120 Vac: 97-136 Vac 120 Vac: 103-130 Vac 120 Vac: 106-127 Vac 230 Vac…
LCD status indicators Status LED Audible Indicator On Audible Indicator Terminates Power On The UPS is supplying AC power to connected equipment. The On…
Status LED Audible Indicator On Audible Indicator Terminates Power On The UPS is supplying AC power to connected equipment. The On Line/On Battery LED…
Vac 230 Vac Description On Line: The UPS is supplying conditioned AC power to connected equipment. Green mode: The UPS is operating at the most efficient…
For more information on System Alerts, contact customer support at the APC by Schneider Electric web site, www.apc.com/support
Configuration Mode The Configuration Mode provides additional options for the UPS. Press and hold the MUTE and DISPLAY buttons for 2 seconds until the system…
The Configuration Mode provides additional options for the UPS. Press and hold the MUTE and DISPLAY buttons for 2 seconds until the system emits a short beep…
Problem and Possible Cause Solution The UPS will not turn on or there is no output The UPS has not been turned on. Press the ON button once to turn on the UPS.…
* Contact Schneider Electric Worldwide Customer Support to determine the age of the installed battery modules. Always recycle used batteries. For information…
1. Shut down and disconnect all connected equipment. 2. Disconnect the unit from utility power. 3. Disconnect all internal and external batteries (if…
section of this manual. Service If the unit requires service, do not return it to the dealer. Follow these steps: 1. Review the Troubleshooting section of the…
Schneider Electric IT Corporation (SEIT), warrants its products to be free from defects in materials and workmanship for a period of two (2) years from the…
10/2018 EN 990-4472E APC by Schneider Electric Worldwide Customer Support Customer support for this or any other APC by Schneider Electric product is available…