Safety Do not install the Back-UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. CAUTION RISK OF HYDROGEN SULPHIDE GAS AND…
Messages SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation and maintenance of the UPS and…
SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. •…
Install PowerChute™ Personal Edition Software APC PowerChute Personal Edition software provides automatic file saving and shutdown of your computer in the…
APC PowerChute Personal Edition software provides automatic file saving and shutdown of your computer in the event of a power outage. Use the USB cable to…
Battery Backup and Surge Protected outlets When the Back-UPS is receiving input power, the Battery Backup with Surge Protection outlets will supply power to…
When the Back-UPS is receiving input power, the Battery Backup with Surge Protection outlets will supply power to connected equipment. During a power outage or…
To conserve electricity, when the device connected to Master Outlet goes into Sleep or Standby mode, or turns Off, the Controlled device(s) will shut down as…
To conserve electricity, configure the Back-UPS to recognize a Master device, such as a desktop computer or an A/V receiver, and Controlled peripheral devices…
The display interface can be configured to be continuously illuminated, or to save energy, it can be configured to darken after a period of inactivity. 1. Full…
Adjust the sensitivity of the Back-UPS to control when it will switch to battery power; the higher the sensitivity, the more often the Back-UPS will switch to…
Use the three buttons on the front panel of the Back-UPS and the display interface to configure the Back-UPS. Front panel MUTE button POWER ON/OFF button…
System Events The Back-UPS will display these event messages Four Beeps Every 30 Seconds Back-UPS is running on battery. You should consider saving any work in…
Audible Indicators Status Icons System Events The Back-UPS will display these event messages Four Beeps Every 30 Seconds Back-UPS is running on battery. You…
Function Button Timing (seconds) UPS Status Description Power Power On 0.2 Off Press POWER to start receiving input utility power. If A/C input power is not…
Problem Possible Cause Corrective Action Back-UPS will not switch on. The Back-UPS is not connected to utility power. Ensure that the Back-UPS is securely…
The battery cartridge typically lasts 3 to 6 years, a shorter period if subjected to frequent outages or elevated temperatures. Battery replacement part for…