38 codes from the official GE PH50S10BNY user manual, in the manual’s own words.
Lower Heating Element Failure Call Service to replace respective heating element
Page 32 of the manual →Compressor Failure or Discharge temp. too high Call service
Page 32 of the manual →Fan Failure Call service F16*, F17 No Hot Water - Mixing Valve Outlet DC TCO Tripped on EMV models or missing jumper wire on non-EMV models Call Service F18*, F63* Mixing Valve Failure Call service
Page 32 of the manual →Runaway Heat Source Call Service
Page 32 of the manual →Tank Temperature (T1) Failure open/short Call Service to replace sensor
Page 32 of the manual →Tank Temperature (T2) Failure open/short Call Service to replace sensor
Page 32 of the manual →Tank Temperature, (T1 or T2) Failure Call Service to replace required sensor
Page 32 of the manual →T3a Sensor (Evap inlet temperature) Failure Call service
Page 32 of the manual →T3b Sensor (Evap outlet temperature) Failure Call service
Page 32 of the manual →T4 Sensor (Compressor outlet) Failure Call service
Page 32 of the manual →T5 Sensor (ambient temperature) Failure Call service F38* Mixing Valve Outlet Temperature (T6) Failure Call Service to replace required sensor F39* Mixing Valve Cold Inlet Temperature (T7) Failure Call Service to replace required sensor F41# Sensing Anode miswired or Empty Tank or Anode Rod Wired Incorrectly Confirm wire is connected to sensing anode terminal. Call Service otherwise.
Page 32 of the manual →Water leak detected (from Leak Detect Module) Inspect for water leak and repair, as required
Page 32 of the manual →Condensate Sensor Failure Call Service to replace required sensor
Page 32 of the manual →Evaporator Not Frost Free. Probable refrigerant leak or Evaporator Not Defrosting Call service
Page 32 of the manual →Seal System Vapor Lock Fault Call service
Page 32 of the manual →T5 Ambient Temperature Check Technician service data - Ambient beyond Heat Pump operating conditions
Page 32 of the manual →Control Board - high temperature fault Call service
Page 32 of the manual →Inverter Fault Call service
Page 32 of the manual →Inverter Software Fault Call service
Page 32 of the manual →Compressor Discharge Temperature Low Call service
Page 32 of the manual →Superheat too low. Possible refrigerant leak. Call service
Page 32 of the manual →Electronic Expansion Valve Out of Range. Probable refrigerant leak. Call service
Page 32 of the manual →Electronic Expansion Valve Out of Range. Probable refrigerant leak; or Refrigerant Leak Test. Probable refrigerant leak. Call service
Page 32 of the manual →Concurrent Load High Current Call service
Page 32 of the manual →AC detection Failure Call Service to confirm wiring is correct
Page 32 of the manual →Tank water temperature is too hot Should self correct
Page 32 of the manual →Incoming water too hot Reduce any preheat of inlet water or call for Service F70# Anode Depleted Call Service to replace sensing anode (see anode replacement section in manual).
Page 32 of the manual →Filter is dirty. If fault repeats after clearing, probable refrigerant leak. Clean Filter. See page 13
Page 32 of the manual →Dry Tank Fault Confirm water in tank. See page 25.
Page 32 of the manual →Voltage too low at power up. Call Service for probable miswire. See page 26.
Page 32 of the manual →Stuck Key Failure Call Service to diagnose and repair
Page 32 of the manual →Leak Sensor detected water Determine source of water leak and correct. Reset shut-off valve, if equipped (see page 13). Call plumber to resolve, otherwise.
Page 32 of the manual →Leak Sensor Battery is low Replace Leak Sensor Battery
Page 32 of the manual →E2 module unplugged or damaged Call Service to diagnose and repair F91 or F92 DataFlash Fault Cycle Power to correct fault after service
Page 32 of the manual →No Personality detected in control board Call Service
Page 32 of the manual →WiFi Board Failure (WiFi icon dark) Call Service to diagnose and repair
Page 32 of the manual →CTA Communication module software fault Call Service
Page 32 of the manual →CTA module disconnected or low battery Reconnect CTA module or replace battery * Applies to models with integrated mixing valve # Applies to models with sensing anode