KAIWEETS True-RMS HT118A Digital Multimeter User Manual - Manualsnap

KAIWEETS True-RMS HT118A Digital Multimeter User Manual

KAIWEETS LOGODigital Multimeter
User Manual
True-RMS
HT118A
KAIWEETS True-RMS HT118A Digital

Safety Instructions

The instrument is designed according to the requirements of the international electrical safety standard IEC61010-1 for the safety requirements of the electronic testing instruments. The design and manufacture of instruments strictly comply with the requirements of IEC61010-1 CAT.III 1000V over-voltage safety standards and pollution level 2.

warning 2 Warning

In order to avoid possible electric shock or personal injury and other safety accidents, please abide by the following specifications:

  • Please read this manual carefully before using the instrument, and pay special attention to safety warning information.
  • Before using the instrument, please check whether there is any crack or plastic damage in the instrument case. If you do, do not use it again.
  • Before using the instrument, please check whether the probe is cracked or If so, please replace the same type and the same electrical specifications.
  • Please comply with local and national safety code. Wear personal protection equipment (such as approved rubber gloves, masks, and flame retardant clothes, ) to prevent being damaged by electric shock and electric arc due to exposed hazardous live conductor

Safety Operating Procedures

  • Before opening the outer cabinet or battery cover, please remove the probe on the instrument. Do not use the instrument in the circumstances that the instrument is taken apart or the battery cover is opened.
  • When using the probe, please put your fingers behind the finger protector of the probe.
  • When measuring, please connect the zero line or the ground line firstly, then connect the live wire; but when disconnecting, please disconnect the live wire firstly, then disconnect the zero line and ground line.
  • When it shows low battery indicator, please replace the battery in time in case of any measurement error.
  • It only meets the safety standards when the instrument is used together with the supplied probe. If the probe is damaged and needs to replace, the probe with same model number and same electrical specifications must be used for

Cautions

  • Do not use the instrument around explosive gas, steam or In wet environment.
  • The instrument shall be used in accordance with the specified measurement category, voltage or current rating.
  • Please be careful if the measurement exceeds 30V AC true RMS, 42V AC peak or 60V DC. There may be danger of electric shock at this kind of voltage
  • By measuring the known voltage to check whether the meter work is normal, if it is not normal or damaged, do not use it again.

Product Description

Symbol Meaning
Symbol 1Dangerous voltage may be presentwarning 2Warning; Important information

AC (Alternating Current)Ac and DcAC and DC
 Direct CurrentDC (Direct current)
EarthEarth groundFuseFuse
LowLow BatteryDoubleDouble insulated
CE SYMBOLComplies with EU directives
Dustbin IconDo not dispose of this product as unsorted municipal waste.

 

CAT IISuitable for testing and measuring circuits directly connected to power points (sockets and similarities) of low voltage power installations.
CAT IIISuitable for testing and measuring circuits connected to the distribution part of low voltage power supply devices in buildings.
CAT IVSuitable for testing and measuring circuits connected to the power supply of low voltage power installations in buildings.
Multimeter Features

KAIWEETS True-RMS HT118A Digital-f key

  1. NCV probe
  2. Flashlight
  3. Red / Green Light
  4. LCD display (bicolored)
  5. Function Key
  6. Rotary Switch V-Terminal
  7. COM Terminal
  8. mA, uA Terminal
  9. WA Terminal
FUNC. Key
Func key 1Press the FUNC button to select the appropriate measurement function.
Func key 2Press the ” HOLD”     key, hold the data for easier recording. Press the button again to remove the hold function.
Func key 3Press the MAX/MIN key to enter the MAX/MIN mode. In this mode, the multimeter will capture the highest/lowest reading it records.
Press and hold this button again to exit the MaxlMin Modes.
Func key 4Backlight: Press once to turn on the display backlight. Press once more to turn off backlight
Flashlight: Long-press more than 2 seconds, to turn on/off the flashlight.
Install or replace the battery

If the ” Low” symbol appears on the display, the battery should be replaced immediately. Disconnect the test leads from the input terminals of the meter and turn off the meter. Remove the rubber sleeve and the screws on the back of the multimeter to replace the battery. After that, re-apply the compartment cover and reinstall the screw firmly.

KAIWEETS True-RMS HT118A Digital- repalce

Sleep Mode
  • The Meter automatically enters sleep mode if there is no operation for 15 minutes to save battery energy. Pressing any button or turning the rotary switch awakes the Meter.
  • If you press the “FUNC.” button and turn on the meter, the sleep mode will be deactivated. After turning off the meter, The Meter will restore Sleep Mode after power off.Sleep mode

Measurement Operation

DC/AC voltage measurement

warning 2 Don’t use it to test DC1000V or AC750V, the instrument may be damaged. Always test known voltage with the meter before use to confirm the instrument function Is Intact.

  1. Turn the rotary switch to”Rotary 2“and select DC/AC voltage function by “FUNC’ key **
  2. Insert the red lead in “KAIWEETS True-RMS HT118A Digital-key ” terminal, insert the black lead in the “COM” terminal.
  3. Connect the test leads to the source or load to be measured.
  4. Read LCD display, when measuring AC voltage the frequency is displayed simultaneously.

KAIWEETS True-RMS HT118A Digital-Dc

DC/AC voltage mV measurement

warning 2 Don’t use it to test DC 250V, the instrument may be damaged. Always test known voltage with the meter before use to confirm the instrument function is intact. Always test known voltage with the meter before use to confirm the instrument function is intact.

  1. Turn the rotary switch to ” Rotary 2 ” and select DC/ AC voltage function by “FUNC.” key 41-41.0.0
  2. Insert the red lead in ” KAIWEETS True-RMS HT118A Digital-key ” terminal insert the black lead in the “COM” terminal.
  3. Connect the test leads to the source or load to be measured.
  4. Read LCD display, when measuring AC voltage the frequency is displayed simultaneously.KAIWEETS True-RMS HT118A Digital-Operation
Frequency/Duty measurement (Hz%)

warning 2 The voltage above 10V can’t be measured, otherwise, the instrument may be damaged.

  1. Turn the rotary switch to “Hz%”
  2. Insert the red lead in ” KAIWEETS True-RMS HT118A Digital-key ” terminal, insert the black lead in “COM”
  3. Connect the test leads to the source or circuit in parallel to be measured, measure the frequency and duty.
  4. Read the measurement result on the screen.

KAIWEETS True-RMS HT118A Digital-Duty

Resistance / Continuity / Diode measurement

warning 2 When measuring the diode on the line, disconnect the power supply and discharge all the high-voltage capacitors. Otherwise, the instrument may be damaged

  1. Turn the rotary switch to ” Func key 5 ” and select the Resistance / Continuity / Diode measurement function by “FUNC.” 2
  2. Insert the red lead in ” KAIWEETS True-RMS HT118A Digital-keyl, insert the black probe in “COM”.
  3. Connect the test leads to the source or circuit in parallel or diode to be measured. Touch the diode anode with the red lead, the black lead contacts the diode cathode.
  4. Read the measurement result on the screen.
FunctionForward DC current is about 2.5mA Reverse DC voltage is about 3V Overload protection:250V
It displays the forward approximate voltage value of the diode.

KAIWEETS True-RMS HT118A Digital-Operation

NCV test

In order to avoid possible accidents such as electric shock or personal injury, please follow the safety regulations.
NCV

  1. Turn the rotary switch to the ” uve ” and Switch to NCV test function by “FUNC.” key. Meter will display “NCV”.
  2. Then NCV probe gradually approaches the detected point.
  3. When the meter senses strong AC signals, the red indicator lights up and meter beeps lastly.

KAIWEETS True-RMS HT118A Digital-Function

Capacitance measurement

warning 2 When measuring Capacitance on the line, disconnect the power supply and discharge all the high-voltage capacitors. Otherwise, the instrument may be damaged and may be struck by electric shocks.

  1. Turn the rotary switch to Rotary.
  2. Insert the red lead in KAIWEETS True-RMS HT118A Digital-key terminal, insert the black lead in “COM” terminal.
  3. Contact the probe to the measured circuit or Capacitance, measure the resistance.
  4. Read the measurement result on the screen.

KAIWEETS True-RMS HT118A Digital-Measurement 1

Temperature Measurement

Don’t touch the charged object when measuring temperature.

  • Turn the rotary switch to the ” C°/’F° “
  • Insert the K-Type thermocouple into The thermocouple’s positive (red) is inserted into the KAIWEETS True-RMS HT118A Digital-keyinput, and the negative end (black) is inserted into the “COM” input.
  • Carefully touch the end of the thermocouple to the object being measured. Wait for the temperature reading to settle, then record the result from the LCD display.

KAIWEETS True-RMS HT118A Digital-Measurement

DC/AC current measurement

warning 2 To avoid damaging the instrument or equipment, check the fuse before measuring and ensure that the measured current does not exceed the rated maximum current; use the correct input.

  1. Tum the rotary switch to “ma 1” or mA2or “mA3and select AC or DC current function by “FUNC.” key
  2. Insert the red lead in “10A” terminal or “10K terminal, insert the black lead in “COM” terminal.
  3. Disconnect the power of the tested circuit; connect the meter to the circuit under test, then turn on the circuit power supply.
  4. Read the measurement result on the screen. When measuring AC current, the frequency is displayed on LCD simultaneously.
Red LeadBlack Lead
ma 1mACOM
mA2mACOM
mA310ACOM

KAIWEETS True-RMS HT118A Digital-Operation

NCV test

warning 2In order to avoid possible accidents such as electric shock or personal injury, please follow the safety regulations.

  1. Turn the rotary switch to the ” Ncv Symbol ” and Switch to the NCV test function by the “FUNC.” key. Meter will display “NCV”.
  2. Then NCV probe gradually approaches the detected point.
  3. When the meter senses weak AC signals, the green indicator lights up, and the meter beeps slowly.
  4. When the meter senses strong AC signals, the red indicator lights up, and the meter beeps lastly.

KAIWEETS True-RMS HT118A Digital-NCV test

Live test

warning 2In order to avoid possible accidents such as electric shock or personal injury, please follow the safety regulations.

  1. Turn the rotary switch to the ” Ncv Symbol “, and Switch to the live test function by the “FUNC.” key. Meter will display “LIVE”.
  2. Insert the red lead in ” KAIWEETS True-RMS HT118A Digital-key ” terminal, Then the probe contact to the test point
  3. When the meter senses weak AC signals, the green indicator lights up, and the meter beeps slowly.
  4. When the meter senses strong AC signals, the red indicator lights up and the meter beeps fastly.

KAIWEETS True-RMS HT118A Digital-Live test

General Specifications

Display Measurements6000 counts, True – RMS
Safety / CompliancesCATIII 1000V,CATIV 600V
Maximum Voltage
(between terminals and earth ground)
DC1000V/AC750V
Fuse protectionmA: F600mA /250V Fuse
10A: F10A /250V fuse
Measurement Speed3 times per second
RangeAuto
Battery2 x 1.5V AM Batteries (included)
TemperatureOperating:0° C ~40° C, <80% RH
Storage:-10~60° C, <70% RH
Humidity10° C non condensing

Accuracy Specifications

The accuracy applies within one year after the calibration. Reference condition: the environment temperature 18°C to 28°C, the relative humidity is no more than 80%.
Accuracy: ± (% reading + word).
DC/AC Voltage

VoltageRangeResolutionAccuracyInput ImpedanceMaximum Input voltage
DC
Voltage
600mV0.1mV±(0 .5% reeding+ 3)10MC)1000V DC
6V0.001V
60V0.01V
600V0.1V
1000VIV
AC Voltage600mV0.1mV± Ws% reeding+5)10M0750V AC
0.001V
60V0.01V
600V0.1V
750VIV

DC/AC Current

CurrentRangeResolutionAccuracyOverload protectionMaximum input current
DC Current600PA0.1PA 4- (1.2% reading+3)PA/mA: F600mA/250V fuse
10A: F10A/250V fuse
mA: 600mA A: 10A
6000PA1PA
613mA0.01mA
600mA0.1rnA
10A0.01A
AC Current600PA0.1PA±(1.5% reading+3)PA/rnA: F600rnAl250V fuse
10A: F10Al250V fuse
mA: 600mA A: 10A
6000PA1PA
60mA0.01mA
600mA0.1mA
10A0.01A

Note: When measuring large current, continuous measurement don’ than 15 seconds.
Resistance/Capacitance

RangeResolutionAccuracyOverload protection
Resistance60000.10±(1.0% reeding+3)250V
6k00.001k0
601(00.01k 0
600k00.1k0
13)(100.001M0±(1.5% mading+3)
60M00.01M0
Capacitance10nF (IF)0.001nF (PP)±(4.0%
readIng+5)
100nF (i$)0.01nF (uF)
1000nF (11F)0.1nF (UF)
10mF0.001mF±(5.0%
reading+5)
100mF0.01mF

Frequency/Duty

RangeResolutionAccuracyOverload protectionVoltage sensitivity
Frequency10Hz0.001Hz±(1.O% reading+3)250V
100Hz0.01Hz
100011z0.1Hz
10kitz0.001kHz
100kHz0.01kHz
1001:814z0.1kHz
10MHz0.001MHz±(3.0%, reading+3)
1-99%0.1%
Duty0- 10MHz/0.2-10VAC
V0 – WO kHz0.5-600V AC
tiA/mAJA0 – 100 kHz/?.?. 1/4 Full range
Reference condition: between 18° C to 28° C. relative humidity is no more than 80.

Maintenance

Clean
If there’s dust on the terminal or the terminal is wet, it may cause measurement errors. Please clean the instrument according to the steps below:

  1. Switch off the power supply of the instrument and remove the test probe.
  2. Turn over the instrument and shake out the dust accumulated in the input terminal. Wipe the outer cabinet with a damp cloth and mild detergent, do not use abrasive or solvent. Wipe contacts in each input terminal with a clean cotton swab soaked in alcohol.

warning 2WARNING
Please always keep the inside of the instrument clean and dry to avoid electric shock or instrument damage.
Replace the Fuse

  1. Turn off the power supply of the instrument, and remove the probe on the instrument.
  2. Use a screwdriver to unscrew screws fixing the back cover, and remove the back cover.
  3. Remove the burnt fuse, replace it with a new fuse of the same specifications, and ensure that the fuse is clamped in the safety clip.
  4. Install the back cover, fix and lock it with screws.

KAIWEETS True-RMS HT118A Digital-Fuse

Three Year Warranty

KAIWEETS will repair, without charge, any defects due to faulty materials or workmanship for three years from the date of purchase provided that:

  • Proof of purchase is produced.
  • Service/repairs have not been attempted by unauthorized persons;
  • The product has been subject to fair wear and tear;
  • The product has not been misused; Defective products will be repaired or replaced, free of charge or at our discretion if sent together with proof of purchase to our authorized distributor(s). For further detail of warranty coverage and warranty repair information, send an email to [email protected].

KAIWEETS True-RMS HT118A Digital-symbol

Documents / Resources

KAIWEETS True-RMS HT118A Digital Multimeter [pdf] User Manual
KAIWEETS, True-RMS, HT118A, Digital, Multimeter

Related Manuals for Honeywell Aquastat L8148A

AstroAI True RMS 6000 Count Digital Multimeter User Manual
AstroAI True RMS 6000 Count Digital Multimeter User Manual

AstroAI True RMS 6000 Count Digital Multimeter User Manual

STEALTH CAM QV18 Digital Scouting Cameras Instruction Manual
STEALTH CAM QV18 Digital Scouting Cameras Instruction Manual

STEALTH CAM QV18 Digital Scouting Cameras Instruction Manual

SONY WF-1000XM4 True Wireless Earbuds Owner's Manual
SONY WF-1000XM4 True Wireless Earbuds Owner's Manual

SONY WF-1000XM4 True Wireless Earbuds Owner's Manual

Levoit Personal True HEPA Air Purifier User Manual
Levoit Personal True HEPA Air Purifier User Manual

Levoit Personal True HEPA Air Purifier User Manual

Heyday True Wireless Earbuds Manual
Heyday True Wireless Earbuds Manual

Heyday True Wireless Earbuds Manual